  • HF2000-MV/2500-MV Centralized inverter
HF2000-MV/2500-MV Centralized inverter
Features:

<1>High YieldEfficient three-level topology, max. inverterefficiency up to 99 %1 or 4 MPPT, wide MPP voltage rangeFull power operation without derating at 50

We're here to help:
Easy ways to get the answers you need.
GET PRICESEND E-MAIL
Share with:
  • Features
  • Specifications
  • Factory&Case
 <1>High Yield

Efficient three-level topology, max. inverterefficiency up to 99 %

1 or 4 MPPT, wide MPP voltage range

Full power operation without derating at 50

One inverter unit fails, the other unit continuesoperation

 <2>  Easy O&M

Integrated zone current monitoring function for fast trouble shooting

Module design and front service, easy for maintenance

DC circuit breaker design for convenient maintenance

 <3> Saved Investment

20-foot container design, no need to build extra inverter house

Integrated MV transformer and LV auxiliary power supply

<4> Grid Support

Compliance with standards: CE, IEC 62109

Low/High voltage ride through (L/HVRT)

Active & reactive power control and power ramp rate control

 

Input (DC)

SG2000-MV

SG2500-MV

Max. PV input voltage

1000 V

Min. PV input voltage / Startup input voltage

460 V / 500 V

520 V / 540 V

MPP voltage range for nominal power

460 850 V

520 850 V

No. of independent MPP inputs

1 or 4

 

No. of DC inputs

16 32

 

Max. PV input current

4880 A

5424 A

Max. DC short-circuit current

5840 A

6780 A

Output (AC)

 

 

 

Nominal AC power (at 55 ˚C)

2000 kW

2520 kW

Max. AC output at PF=1 (at 45 ˚C)

2200 kW

2772 kW

Max. AC apparent power (at 45 ˚C)

2200 kVA

2772 kVA

Max. inverter output current

4032 A

4444 A

AC voltage range

10 35 kV

 

Nominal grid frequency / Grid frequency

50 Hz / 45 55 Hz, 60 Hz / 55 65 Hz

 

THD

< 3 % (at nominal power)

 

DC current injection

< 0.5 % In

 

Power factor at nominal power / Adjustable power factor

> 0.99 / 0.8 leading 0.8 lagging

 

Feed-in phases / Connection phases

3 / 3

 

Efficiency

 

 

 

Inverter max. efficiency / Inverter Euro efficiency

99.0 % / 98.7 %

 

Transformer

 

 

 

Transformer rated power

2000 kVA

2520 kVA

Transformer Max.power

2200 kVA

2772 kVA

LV / MV volatage

0.315 kV / 10 35 kV

0.360 kV / 10 35 kV

Transformer Vector

Dy11

 

Oil type

Mineral oil (PCB free) or degradable oil on request

 

Protection

 

 

 

DC reverse connection protection

Yes

 

DC input protection

Circuit breaker

 

Inverter output protection

Circuit breaker

 

AC output protection

Circuit breaker * / Load switch + fuse **

 

Overvoltage protection

DC Type II / AC Type II

 

Grid monitoring / Ground fault monitoring

Yes / Yes

 

Insulation monitoring

Yes

 

Overheat protection

Yes

 

Anti-PID function

Optional

 

General Data

 

 

 

Dimensions (W*H*D)

6058*2896*2438 mm

 

Weight

17 T

 

Degree of protection

IP54

 

Auxiliary power supply

220 Vac, 2 kVA / Optional: 380 Vac, up to 15 kVA

 

Operating ambient temperature range

-35 to 60 (> 50 derating)

 

Allowable relative humidity range (non-condensing)

0 - 95 %

 

Cooling method

Temperature controlled forced air cooling

 

Max. operating altitude

1000 m (standard) / > 1000 m (optional)

 

Display

Touch screen

 

Communication

Standard: RS485, Ethernet; Optional: Optical fiber

 

Compliance

CE, IEC 62109

 

INQUIRY:

Please enter your question and contact information. We will get back to you as soon as possible.