  • HF1000MX Centralized inverter
HF1000MX Centralized inverter
Features:

<1>High YieldMax. efficiency up to 98.8%Long-term overload at 1.1 PnFull power operation without derating at 55 ℃ <2> Easy O&MIntegrated zone current monitor

We're here to help:
Easy ways to get the answers you need.
GET PRICESEND E-MAIL
Share with:
  • Features
  • Specifications
  • Factory&Case
 <1>High Yield

Max. efficiency up to 98.8%

Long-term overload at 1.1 Pn

Full power operation without derating at 55

 <2>  Easy O&M

Integrated zone current monitoring function for fast trouble shooting

All components front accessible easy for maintenance

 <3> Saved Investment

Max. DC/AC ratio up to 1.5

Integrated with recombiner

<4> Grid Support

Compliance with standards: UL1741, IEEE 1547, IEEE 1547.1, CSA C22.2 107.1-01

Low/High voltage ride through (L/HVRT)

 

Input (DC)

 

Max. PV input voltage

1000 V

Min. PV input voltage / Startup input

550 V / 570 V

MPP voltage range for nominal power

570 850 V

No. of independent MPP inputs

1

No. of DC inputs

1, 8 12

Max. PV input current

2000 A

Max. DC short-circuit current

2400 A

PV array configuration

Negative grounding (standard), positive grounding or floating (o ptional)

Output (AC)

 

Nominal AC power (at 55 ˚C)

1000 kW

Max. AC output power at PF=1 (at 50 ˚C)

1100 kW

Max. AC apparent power (at 50 ˚C)

1100 kVA

Max. AC output current

1650 A

Nominal AC voltage

385 V

AC voltage range

383 424 V

Nominal grid frequency / Grid

50 Hz / 45 55 Hz, 60 Hz / 55 65 Hz

THD

< 3 % (at nominal power)

DC current injection

< 0.5 % In

Power factor at nominal power / Adjustable power factor

> 0.99 / 0.8 leading 0.8 lagging

Feed-in phases / Connection phases

3 / 3

Efficiency

 

Max. efficiency / CEC efficiency

98.8 % / 98.5 %

Protection

 

DC input protection

Load switch + fuse

AC output protection

Circuit breaker

Overvoltage protection

DC Type II / AC Type II

Grid monitoring / Ground fault monitoring

Yes / Yes

Overheat protection

Yes

General Data

 

Dimensions (W*H*D)

102.3''*85.2''*39.4'' 2598*2164*1000 mm

Weight

4519.5 lb 2050 kg

Isolation method

Transformerless

Degree of protection

NEMA 3R

Night power consumption

< 20 W

Operating ambient temperature range

-22 to 140 (> 131 derating) -30 to 60 °C (> 55 °C derating)

Allowable relative humidity range (non-condensing)

0 95 %

Cooling method

Temperature controlled forced air cooling

Max. operating altitude

13123 ft (> 6561 ft derating) 4000 m (> 2000 m derating)

Display

Touch screen

Communication

RS485, Ethernet

Compliance

UL 1741, IEEE 1547, CSA C22.2 #107.1-01

 